Medical equipment sourcing
Pioon 1470nm Diode Laser for Skin Re
Interested in this product?Ask about specifications, quantities and delivery.
Associated tags
Product summary
GoldHealth Medical: Revolutionizing Skin Rejuvenation and Lipolysis
GoldHealth Medical introduces an advanced diode laser system designed for face lifting, endolifting, and lipolysis. Engineered with precision, this 1470nm laser device offers unparalleled skin rejuvenation capabilities, making it an essential tool for modern medical practices.
Key Features and Benefits:
- Advanced Laser Technology: Utilizes a 1470nm wavelength for optimal skin tightening and fat reduction.
- Versatile Applications: Ideal for face lifting, endolifting, and effective lipolysis treatments.
- Unmatched Safety Standards: Designed to meet the highest safety and efficacy benchmarks for medical-grade equipment.
- Customizable Solutions: Tailored configurations available for hardware, software, and power settings to suit specific clinical needs.
Product Specifications:
- Laser Handpiece for Lipolysis: High-performance handpiece engineered for precision and comfort during procedures.
- Endolifting Fiber Tips with SMA905 Connector: Ensures seamless integration and consistent performance.
- Intelligent Operating System: Fully self-developed software for intuitive operation and enhanced treatment outcomes.
Why Choose GoldHealth Medical?
GoldHealth Medical is a globally recognized manufacturer of medical laser equipment, not a general electronics producer. Our credentials include: - Class III Medical Device Manufacturer: Approved by China's SFDA and compliant with ISO13485 standards. - Global Certifications: EU CE certification (Notified Body Code: 0123), US FDA 510(k) clearance, and registrations in over 40 countries. - Comprehensive Quality Assurance: Rigorous testing by third-party agencies ensures compliance with international medical device standards.
Why Invest in Genuine Medical Devices?
- Safety and Effectiveness: Medical-grade lasers are designed to ensure patient safety and clinical efficacy, adhering to strict regulatory standards.
- Traceability and Risk Management: Every stage, from R&D to production, is meticulously monitored to minimize risks and ensure reliability.
- Superior Components: All critical components meet medical-grade specifications, ensuring durability and performance unmatched by non-medical alternatives.
- Regulatory Compliance: Non-medical devices are not approved for clinical use, making them inherently unreliable and potentially hazardous.
Commitment to Excellence:
GoldHealth Medical is dedicated to delivering safe, effective, and innovative solutions. Our products undergo extensive clinical testing and are supported by a robust warranty and after-sales service program: - 5-Year Service Life: Comprehensive testing ensures long-term reliability. - Free Repairs and Support: Non-human damage repairs, including freight, are covered during the product lifecycle. - Customization and Training: From hardware to software, our systems are fully customizable. We also provide clinical training and technical support through partnerships with global distributors and academic institutions.
Global Reach and Expertise:
With a presence in over 80 countries, GoldHealth Medical offers expert guidance on product registration and customs clearance. Our legal team ensures smooth entry into your market, minimizing risks of delays or confiscation.
GoldHealth Medical: Where innovation meets precision, empowering healthcare professionals worldwide with cutting-edge technology.
Shipping & Delivery FAQ
How are products prepared before shipment?
Each item is checked against the catalog record, protected with suitable packaging materials, and prepared with available product documentation for procurement review.
Can you support international delivery requests?
The support team can coordinate delivery options by destination, product type, and documentation requirements before confirming availability.
Are fragile or calibrated products handled differently?
Sensitive products are packed with additional cushioning and handling notes; calibration or compliance documents can be reviewed during the inquiry process.
How can I estimate lead time?
Lead time depends on stock status, destination, carrier availability, and any requested documentation. Contact the product team for a product-specific estimate.
Before you choose a medical product
Practical answers about product configuration, consumables, documents, quantities and support before a medical supply inquiry.
How do I confirm the right model and configuration?
Include the product reference, intended care setting and the functions or dimensions you need. Ask which accessories are included and which are optional. Images and a shared product name may cover more than one configuration, so confirm the exact version in the supplier response.
Will accessories or consumables fit my existing equipment?
Provide the equipment manufacturer, model and the relevant connector, size or part reference. Request compatibility information for the specific combination rather than relying on visual similarity. Follow the equipment and accessory manufacturers' instructions.
Which product documents can I request?
Depending on the product, useful requests may include a specification sheet, instructions for use, packaging details or available regulatory documents. State your destination market and the exact document required. A catalog listing does not establish that every model has a particular approval or certification.
Are all consumables sterile or suitable for single use?
No assumption should be made across the catalog. Check the labeling and instructions for the exact product, including whether it is supplied sterile, its stated use, expiry information and storage requirements. Ask for clarification before purchasing if these details are missing.
Can I ask about samples, pack sizes or minimum quantities?
Yes. Tell us the item reference, the quantity you want to evaluate and the quantity expected for the project. Sample availability, pack sizes and minimum purchase quantities depend on the product and must be confirmed individually.
What should I confirm for installation and ongoing use?
For equipment, ask about power supply, installation space, setup instructions, training materials, spare parts and the applicable service or warranty terms. Confirm which support is available for the selected model and destination before agreeing to a purchase.
How are price, lead time and delivery confirmed?
Send quantities, destination and required timing with your inquiry. Request a written response covering the selected configuration, packing, commercial terms and delivery estimate. Published product information is a starting point; an inquiry is not an order confirmation.
About Gold Health
Medical supplies for the way care is delivered
Explore Gold Health: medical equipment, clinical consumables and veterinary supplies for professional procurement.
Different care settings, one place to begin
A hospital department, an independent clinic, a laboratory and a veterinary practice can have very different purchasing needs. Our catalog brings equipment, instruments and everyday supplies into a browsable starting point for these different settings.
Explore by category, inspect the product images and use the listed details to build a shortlist. Availability and the exact configuration are confirmed for the selected item when you contact the team.
Look beyond the product name
A useful product choice depends on more than a headline. Dimensions, materials, model references, accessories, packaging and instructions can all affect whether an item belongs on your purchasing list.
We encourage buyers to identify these details early and ask for the product-specific information they need before making a decision.
Equipment and consumables need different questions
For equipment, ask about the supplied configuration, compatible accessories, electrical requirements and available service information. For consumables, confirm the stated intended use, pack quantity, storage conditions and any sterile or single-use labeling for that exact item.
The catalog helps organize the conversation. Product suitability and any clinical use must be assessed using the relevant manufacturer instructions and qualified professional review.
Turn a shortlist into a useful conversation
Send the product names or references together with your quantities, destination and preferred timing. If several items form one project, explain which accessories or consumables need to work together.
This gives the team a practical basis for discussing specifications, available documents, packaging and the next commercial steps. Please keep patient information and other sensitive records out of your inquiry.
Product attributes
Brand Name: GoldHealth Medical
Instrument Classification: Class III Medical Device
Safety Standard: ISO13485, Class III Medical Devices
Product Highlights
- Unmatched Precision and Performance: Engineered with a 1470nm±30nm wavelength and 15W power output, this device delivers exceptional results in both continuous and pulsed operating modes.
- Advanced Display Technology: Features a 7-inch RETINA touch display with HDR1200p—the highest resolution in the industry—offering unparalleled clarity and intuitive control.
- Superior Build Quality: Constructed with five-axis CNC metal for excellent heat dissipation, A0 fireproof grade PC+ABS, and German Bayblend FR1514 for durability and safety.
- Customizable Operating System: Equipped with an independently developed OS that supports any customization to meet your specific needs.
- Precision Aiming Beam: Includes a 650nm<2mW adjustable-density aiming beam for enhanced accuracy during procedures.
- Versatile Fiber Connection: SMA905 direct connect compatible with medical fibers >400um, along with multi-purpose handpieces for diverse applications.
Technical Specifications
- Wavelength: 1470nm±30nm
- Power Output: 15W
- Operating Modes: Continuous / Pulsed
- Aiming Beam: 650nm<2mW, adjustable density
- Fiber Compatibility: SMA905 direct connect, medical fibers >400um
- Display: 7-inch RETINA touch display, HDR1200p
- Weight (Without Case): <2kg NW
- Power Source: Electric
Certifications and Compliance
- Quality Certifications: CE0123, ANVISA, ISO13485, Class III Medical Devices
- Safety Standards: ISO13485
Warranty and After-Sales Service
- Warranty: 3 years
- After-Sales Support: Includes remote upgrades, on-site inspection, and maintenance services to ensure uninterrupted performance.
Packaging Details
- Single Package Size: 67 x 47 x 36 cm
- Single Gross Weight: 15.000 kg
Shelf Life
- Duration: 3 years
GoldHealth Medical’s advanced technology and commitment to quality make this device the ideal choice for hospitals, clinics, research institutions, and home healthcare providers seeking precision, reliability, and innovation.
Continue your equipment review