Total Bilirubin Meter by GoldHealth Medical
Engineered for precision, the Total Bilirubin Meter delivers quantitative determination of total bilirubin in blood with cutting-edge photometric technology. Designed for healthcare professionals and institutions, this device ensures accurate, rapid, and reliable results, making it indispensable in clinical diagnostics.
Key Features and Technical Specifications:
- Measurement Principle: Advanced direct photometric technology for unparalleled accuracy.
- Measuring Range: 0–30 mg/dL, catering to a wide spectrum of diagnostic needs.
- Sample Collection:
- Blood samples are collected using a 75mm/60μL disposable capillary with a diameter of 1.3mm–1.4mm.
- The capillary is centrifuged for 5 minutes at 3000 RPM to separate serum and blood cells.
- Measurement Process:
- Insert the prepared capillary into the measuring well.
- Results are displayed within 10 seconds, ensuring efficiency in fast-paced environments.
- Sample Volume: Requires only 40–45 μL (2/3–3/4 of the capillary’s total volume), minimizing sample waste.
- Light Source: Equipped with a long-life white LED, ensuring consistent performance and reduced maintenance.
- Photometer: Features a bi-chromatic filter system with wavelengths of 405nm (M) and 578nm (S) for precise readings.
- Built-in Printer: Includes a 58mm thermal printer for instant, hard-copy results.
- Display: A 16×2 ASC code LCD with backlight for clear visibility in any lighting condition.
- Connectivity: Offers a standard RS232 port and USB port for seamless data transfer and integration with external systems.
- Compact Design: Dimensions of 250(L) x 190(W) x 85(H) mm, ensuring portability and ease of placement in any clinical setting.
Why Choose GoldHealth Medical’s Total Bilirubin Meter?
- Speed and Precision: Delivers results in just 10 seconds without compromising accuracy.
- Ease of Use: Simplified workflow with minimal manual intervention, making it ideal for busy laboratories and clinics.
- Durability: Long-life LED and robust design ensure consistent performance over time.
- Versatility: Suitable for hospitals, research labs, rehabilitation centers, and home healthcare settings.
- Cost Efficiency: Reduces operational costs while maintaining high diagnostic standards.
Applications:
- Hospitals and clinics for routine bilirubin testing.
- Research institutions conducting biochemical analyses.
- Rehabilitation centers monitoring liver function.
- Home healthcare setups for convenient and reliable diagnostics.
GoldHealth Medical is committed to delivering innovative, high-quality medical solutions that empower healthcare providers worldwide. Our Total Bilirubin Meter exemplifies this commitment, combining advanced technology with user-centric design to meet the evolving needs of modern medicine.
Choose GoldHealth Medical for precision, reliability, and excellence in every diagnostic step.
Common Shipping and Delivery Considerations
- Packaging:
Medical devices need secure packaging to avoid damage during transit, including shock-absorbing materials or custom foam inserts. - Compliance with Regulations:
Ensure compliance with local and international standards (e.g., FDA, CE) and shipping regulations like Good Distribution Practice (GDP). - Temperature Control:
Some devices require temperature-controlled shipping (e.g., refrigerated trucks or special packaging) to maintain product integrity. - Tracking and Documentation:
Shipments should be tracked with necessary documents like invoices, certificates, and import/export paperwork. - Lead Time:
Plan ahead for lead times, which can vary depending on the equipment size and delivery location. - Insurance: Due to the high value of medical equipment, consider insurance to protect against loss or damage during transit.
- Customs and Import Regulations: Account for customs procedures and tariffs when shipping internationally, ensuring proper documentation.
- Special Handling:
Fragile or hazardous medical devices may require special handling, with clear labeling to ensure proper care. - Delivery Method:
Choose the appropriate shipping method (air, sea, or ground) depending on the equipment’s size, value, and urgency. - Returns and Reverse Logistics:
Have a clear process in place for returns, repairs, and warranty claims if necessary.
Frequently Asked Questions
39
Stores In World
97
Cities With Free Shipping
300+
Five Star Rating
Our mission and vision
At Gold Health Medical, our vision is to revolutionize healthcare by providing high-quality medical equipment that enhances patient care and improves healthcare efficiency. We are committed to being a trusted partner for medical professionals and institutions, ensuring they have access to the latest and most reliable medical technology.
Our goal is to bridge the gap between innovation and accessibility, making advanced healthcare solutions available to providers worldwide. Through excellence in service, integrity, and continuous improvement, we strive to empower healthcare professionals with the tools they need to deliver superior patient outcomes.
Together, we are shaping the future of medical care—one innovation at a time.
What Our Customers Say
At Gold Health Medical, we take pride in delivering high-quality medical equipment and exceptional customer service. Here’s what our satisfied clients have to say about their experience with us:
Brand Name: GoldHealth Medical
Product Name: Total Bilirubin Meter for Neonates
Product Overview
The Total Bilirubin Meter for Neonates by GoldHealth Medical is a state-of-the-art diagnostic tool designed to provide highly accurate and reliable measurements of total bilirubin levels in neonatal blood. Engineered with precision and sensitivity exceeding 99%, this device ensures rapid, non-invasive testing, making it an indispensable asset for healthcare professionals in hospitals, clinics, and research institutions. Its sleek white design and advanced LCD display deliver both functionality and modern aesthetics, setting a new standard in neonatal care.
Key Features
- Instrument Classification: Class II medical device
- Application: Measures total bilirubin levels in neonatal blood with exceptional accuracy
- Sensitivity: > 99%, ensuring precise and dependable results
- Display: High-resolution LCD for clear and intuitive readings
- Power Supply: AC100-250V, adaptable to global power standards
- Certifications: Compliant with CE and ISO standards for safety and quality
Technical Specifications
- Type: Reflector apparatus technology for enhanced performance
- Color: Elegant white finish
- Warranty: Comprehensive 3-year warranty for peace of mind
- Packaging: Export-grade packaging to ensure safe delivery
Supply and Delivery
- Minimum Order Quantity (MOQ): 1 unit
- Supply Capacity: Up to 1,000 units per month to meet high demand
- Port of Delivery: Guangzhou
GoldHealth Medical’s Total Bilirubin Meter for Neonates combines cutting-edge technology with user-centric design, empowering healthcare providers to deliver superior care to the most vulnerable patients. Whether for clinical diagnostics, research, or home healthcare, this device is engineered to exceed expectations.