GoldHealth Medical presents an advanced Stress ECG Analysis System, designed to redefine precision and reliability in cardiac diagnostics. This system integrates a state-of-the-art sampling hardware device, a specialized software platform, and compatible exercise equipment, offering a comprehensive solution for monitoring and analyzing heart function during physical stress.

Key Features

  • Real-Time ECG Waveform Printing: Captures and stores the entire ECG process with high accuracy, ensuring no critical data is missed.
  • Dynamic ST Segment Monitoring: Provides real-time observation of ST segment changes with enlarged display options and automatic ST-related data calculations.
  • Advanced Anti-Interference Technology: Minimizes baseline drift, EMG interference, and AC noise, delivering stable and clear ECG waveforms.
  • Customizable Exercise Protocols: Supports both standard and user-defined exercise schemes, with automated alerts for printing and blood pressure measurements.
  • Event Marking and Comparison: Allows operators to tag events during exercise, enabling post-exercise review, editing, and printing of marked ECG waveforms.
  • Comprehensive Trend Analysis: Displays and prints trend charts for multiple parameters, including heart rate (HR), blood pressure (BP), metabolic equivalents (METS), ST segment metrics, and more.
  • Post-Exercise Review: Offers dynamic and static review functions to visualize the entire exercise testing process.
  • Efficient Case Management: Features case import/export functionality with file compression, reducing storage space while maintaining quick access.
  • Customizable System Settings: Includes language switching, waveform display formats, background color adjustments, and filter settings for tailored operation.
  • Integrated Functional Tools: Provides utilities for device management, case statistics, and other operational tasks.
  • Wireless ECG Sampling: Enhances mobility and reduces interference during data collection.
  • Universal Compatibility: Works seamlessly with various types of exercise equipment.

Performance Specifications

  • Patient Leak Current: <10µA
  • Input Impedance: ≥50MΩ
  • Frequency Response: 0.05Hz~150Hz (-3dB~+0.4dB)
  • Time Constant: ≥3.2s
  • Common Mode Rejection Ratio (CMRR): >60dB, >100dB (with filter enabled)
  • Calibration Voltage: 1mV
  • Sampling Frequency: Up to 1000 Hz
  • Sampling Accuracy: Up to 24 bits
  • Input Loop Current: ≤50nA
  • Polarization Resistance Voltage: ±500mV
  • Noise Level: ≤15µVp-p
  • Safety Classification: Internally powered, Type BF equipment

Physical Characteristics

  • Dimensions: 94mm (L) x 66mm (W) x 31mm (H)
  • Weight: Approximately 94.6g (excluding battery)

Included Accessories

  • Wireless network card
  • Lead cables
  • Electrodes
  • Grounding wire
  • Velcro straps (2 pieces)
  • Serial-port cable
  • Installation CD
  • Software protection key
  • Serial-port card

GoldHealth Medical’s Stress ECG Analysis System stands out with its precision engineering, user-centric design, and robust performance. It empowers healthcare professionals with reliable data and intuitive tools, ensuring accurate diagnoses and enhanced patient care.

Common Shipping and Delivery Considerations

  • Packaging:
    Medical devices need secure packaging to avoid damage during transit, including shock-absorbing materials or custom foam inserts.
  • Compliance with Regulations:
    Ensure compliance with local and international standards (e.g., FDA, CE) and shipping regulations like Good Distribution Practice (GDP).
  • Temperature Control:
    Some devices require temperature-controlled shipping (e.g., refrigerated trucks or special packaging) to maintain product integrity.
  • Tracking and Documentation:
    Shipments should be tracked with necessary documents like invoices, certificates, and import/export paperwork.
  • Lead Time:
    Plan ahead for lead times, which can vary depending on the equipment size and delivery location.
  • Insurance: Due to the high value of medical equipment, consider insurance to protect against loss or damage during transit.
  • Customs and Import Regulations: Account for customs procedures and tariffs when shipping internationally, ensuring proper documentation.
  • Special Handling:
    Fragile or hazardous medical devices may require special handling, with clear labeling to ensure proper care.
  • Delivery Method:
    Choose the appropriate shipping method (air, sea, or ground) depending on the equipment’s size, value, and urgency.
  • Returns and Reverse Logistics:
    Have a clear process in place for returns, repairs, and warranty claims if necessary.
#Questions & Answer

Frequently Asked Questions

39

Stores In World

97

Cities With Free Shipping

300+

Five Star Rating

Our mission and vision

At Gold Health Medical, our vision is to revolutionize healthcare by providing high-quality medical equipment that enhances patient care and improves healthcare efficiency. We are committed to being a trusted partner for medical professionals and institutions, ensuring they have access to the latest and most reliable medical technology.

Our goal is to bridge the gap between innovation and accessibility, making advanced healthcare solutions available to providers worldwide. Through excellence in service, integrity, and continuous improvement, we strive to empower healthcare professionals with the tools they need to deliver superior patient outcomes.

Together, we are shaping the future of medical care—one innovation at a time.

What Our Customers Say

At Gold Health Medical, we take pride in delivering high-quality medical equipment and exceptional customer service. Here’s what our satisfied clients have to say about their experience with us:

Product Overview
GoldHealth Medical proudly presents the Stress Test ECG Machine, a cutting-edge diagnostic tool designed to elevate cardiovascular assessments. Engineered for precision and reliability, this Class II medical instrument is ideal for hospitals, clinics, research labs, and home healthcare environments.

Key Features
- Advanced Diagnostic Capabilities: Utilizes state-of-the-art laser technology for accurate and reliable ECG readings.
- Seamless Connectivity: Equipped with WiFi communication mode for effortless data transfer and integration with digital health systems.
- Durable Construction: Crafted from high-quality, medical-grade plastic ensuring longevity and hygiene.
- Electric Power Source: Designed for consistent performance with an electric power supply.

Technical Specifications
- Instrument Classification: Class II medical device
- Shelf Life: 3 years
- Warranty: Comprehensive 1-year coverage for peace of mind
- Quality Certifications: CE and ISO approved, guaranteeing compliance with international safety and performance standards

After-Sales Support
- Dedicated Online Technical Support: Ensures uninterrupted operation and quick resolution of queries.

Unique Selling Points
- Precision Redefined: Delivers unparalleled accuracy in stress test ECG diagnostics.
- User-Centric Design: Combines intuitive operation with robust performance, catering to both professionals and home users.
- Global Reliability: Designed in China with a focus on meeting the needs of a global audience.

GoldHealth Medical’s Stress Test ECG Machine is more than a diagnostic tool—it’s a commitment to advancing healthcare excellence.

RELATED PRODUCTS