Product Overview
The GoldHealth Medical lab incubator is a groundbreaking solution designed for the incubation of mammalian cells, plant tissues, bacteria, fungi, and viruses. Engineered to meet the rigorous demands of molecular biology research, this incubator offers unparalleled flexibility and precision. Its modular design allows users to control temperature, CO2 concentration, and shaking functions independently, enabling the creation of tailored experimental conditions.
This incubator is available in four configurations:
– Electrothermal Thermostatic Incubator: Ideal for precise temperature control.
– CO2 Cell Incubator: Adds CO2 concentration control for cell culture applications.
– Thermostatic Shaking Incubator: Incorporates a shaking mechanism for dynamic incubation.
– Multifunctional Incubator (Electrothermal Type): Combines temperature, CO2 control, and shaking for advanced research needs.
Key Features and Specifications
– Outer Dimensions: 65×65×104 cm
– Work Room Dimensions:
– Without shaking system: 50×45×70 cm
– With shaking system: 50×45×56 cm
– Volume:
– Without shaking system: 160L
– With shaking system: 125L
– Controller: LED display with button input for intuitive operation.
– Shaker Volume: Supports 500ml×9 or 250ml×9 containers.
– Temperature Range: RT+5°C to 60°C.
– Temperature Fluctuation: ±0.2°C for exceptional stability.
– Temperature Uniformity: ±0.5°C for consistent results.
– CO2 Concentration Range: 0% to 20%.
– CO2 Concentration Fluctuation: ±0.2% for precise gas control.
– Shaking Mode: Rotating shaking with an amplitude of 30mm and adjustable speed from 40 to 250 rpm.
– Timing Range: Continuous operation or programmable cycles from 1 to 99 hours.
– Temperature Sensor: PT 100 Resistance for accurate monitoring.
– CO2 Sensor: High-performance imported infrared sensor for reliable detection.
– Loading Shelves: Includes 2 shelves for optimal organization.
Advanced Safety Features
– Over-temperature self-protection heater.
– Temperature deviation alarm.
– CO2 concentration deviation alarm.
– Smart door control: When the door is opened, heating is cut off, CO2 input begins, and the fan activates. Shaking and refrigerant functions are also engaged as needed.
Unique Selling Points
– Modular Design: Customize your incubator to match specific research requirements.
– Precision Control: Achieve exacting standards in temperature, CO2 levels, and shaking dynamics.
– Versatility: Suitable for a wide range of applications, from cell culture to microbiology.
– Reliability: Equipped with advanced sensors and safety mechanisms to ensure consistent performance.
Applications
This incubator is ideal for hospitals, clinics, research labs, and biotech facilities. It supports applications in cell culture, microbiology, plant tissue research, and molecular biology experiments.
Why Choose GoldHealth Medical?
GoldHealth Medical is committed to delivering innovative, high-quality medical equipment that empowers researchers and healthcare professionals. Our products are designed with precision, durability, and user-centric features to meet the evolving needs of modern science.
Explore the possibilities with GoldHealth Medical’s advanced lab incubator – where precision meets versatility.
Common Shipping and Delivery Considerations
- Packaging:
Medical devices need secure packaging to avoid damage during transit, including shock-absorbing materials or custom foam inserts. - Compliance with Regulations:
Ensure compliance with local and international standards (e.g., FDA, CE) and shipping regulations like Good Distribution Practice (GDP). - Temperature Control:
Some devices require temperature-controlled shipping (e.g., refrigerated trucks or special packaging) to maintain product integrity. - Tracking and Documentation:
Shipments should be tracked with necessary documents like invoices, certificates, and import/export paperwork. - Lead Time:
Plan ahead for lead times, which can vary depending on the equipment size and delivery location. - Insurance: Due to the high value of medical equipment, consider insurance to protect against loss or damage during transit.
- Customs and Import Regulations: Account for customs procedures and tariffs when shipping internationally, ensuring proper documentation.
- Special Handling:
Fragile or hazardous medical devices may require special handling, with clear labeling to ensure proper care. - Delivery Method:
Choose the appropriate shipping method (air, sea, or ground) depending on the equipment’s size, value, and urgency. - Returns and Reverse Logistics:
Have a clear process in place for returns, repairs, and warranty claims if necessary.
Frequently Asked Questions
39
Stores In World
97
Cities With Free Shipping
300+
Five Star Rating
Our mission and vision
At Gold Health Medical, our vision is to revolutionize healthcare by providing high-quality medical equipment that enhances patient care and improves healthcare efficiency. We are committed to being a trusted partner for medical professionals and institutions, ensuring they have access to the latest and most reliable medical technology.
Our goal is to bridge the gap between innovation and accessibility, making advanced healthcare solutions available to providers worldwide. Through excellence in service, integrity, and continuous improvement, we strive to empower healthcare professionals with the tools they need to deliver superior patient outcomes.
Together, we are shaping the future of medical care—one innovation at a time.
What Our Customers Say
At Gold Health Medical, we take pride in delivering high-quality medical equipment and exceptional customer service. Here’s what our satisfied clients have to say about their experience with us:
Product Name: Thermostatic CO2 Incubator by GoldHealth Medical
Key Features and Benefits:
- Precision Control: Equipped with an advanced LED display and button input for seamless operation, ensuring accurate temperature and CO2 concentration management.
- Optimal Performance: Designed for consistent results with a temperature fluctuation of ±0.2°C and uniformity of ±0.5°C.
- Versatile Capacity: Offers two workroom dimensions (504570 cm or 504556 cm) and volumes of 160L or 125L to suit diverse laboratory needs.
- Enhanced Durability: Constructed with high-quality metal and plastic materials for long-lasting reliability.
- Safety and Compliance: Class II instrument classification with ISO quality certification, ensuring adherence to global medical standards.
Technical Specifications:
- Temperature Range: RT+5°C to 60°C
- CO2 Concentration Range: 0% to 20%
- Shaker Volume: Supports 500ml9 or 250ml9 configurations
- Outer Dimensions: 6565104 cm
- Power Source: Electric
Packaging and Delivery:
- Packaging: Securely packed in a robust wooden case to ensure safe transportation.
- Port of Origin: Guangzhou, China
Warranty and Support:
- Warranty: Comprehensive 1-year warranty for peace of mind.
- After-Sale Service: Access to online technical support for uninterrupted performance.
Supply Capability:
- Monthly Supply: Up to 3000 sets per month, ensuring timely availability for bulk orders.
GoldHealth Medical’s Thermostatic CO2 Incubator is engineered to deliver unparalleled precision, reliability, and versatility, making it the ideal choice for hospitals, research labs, and advanced medical facilities worldwide.